THE WILDCAT POWER PACK

The WILDCAT PowerPack is part of the WILDCAT Engineered Power Solutions portfolio and is a parallel power genset package that consists of a Dual Core (2 gensets), Quad Core (4 gensets), or Octa Core (8 gensets) powertrain engineered to provide prime power or emergency standby power in a variety of applications.

  • 120KW to 7200KW

  • Natural Gas, Propane and Diesel options

  • Prime and Emergency Standby Power configurations

  • Pairs with battery packs, solar, and wind power systems

  • Optional CHP designs available

  • Up to 20% reduced footprint compared to the competition.

  • Ideal for applications and market segments such as Data Centers, Utilities, Peak Shaving, Oil & Gas, Microgrids, Distributed Energy Projects, and Large Backup Power Projects.

Parallel Power Offering Redundancy and Resiliency

The WILDCAT PowerPack is a parallel power genset package that consists of a Dual Core (2 gensets), Quad Core (4 gensets), or Octa Core (8 gensets) powertrain engineered to provide prime power or emergency standby power in a variety of applications.

PowerPack Diesel Emergency Standby Power: 120KW to 7,200KW

PowerPack Diesel Prime Power: 1,000KW to 5,000KW

PowerPack Gaseous Emergency Standby Power: 250KW to 3,520KW

PowerPack Gaseous Prime Power: 300KW to 1,560KW

Compact Design

Achieve up to a 20% reduction in footprint, making it the ideal solution for sites with complex conditions and customers facing space constraints.

Optimal Efficiency

Experience superior fuel efficiency that not only reduces operational costs but also accelerates CAPEX recovery in the shortest possible timeframe.

Flexibility

Tailored to support applications and customer needs where load conditions vary or demand flexibility, ensuring seamless and reliable performance.

Emissions Compliance

Advanced emission control technology significantly reduces environmental impact, aligning with the latest regulatory standards.

Ease of Use

Designed with intuitive control systems and simplified maintenance for hassle-free operation and management.

Applications & Industries

DATA CENTERS

MICROGRIDS

OIL & GAS

PEAK SHAVING

UTILITIES

LARGE BACKUP POWER PROJECTS

Power Pack Diesel Emergency Standby Power Options

120KW: Dual Core KOEL 4R810TA1 Engine + Stamford Alternator + Deep Sea Controls

300KW: Dual Core HDI DP054CBK Engine + Stamford Alternator + Deep Sea Controls

400KW: Dual Core HDI DP086CAK Engine + Stamford Alternator + Deep Sea Controls

1000KW: Dual Core HDI DX15 Engine + Stamford Alternator + Deep Sea Controls

1250KW: Dual Core Volvo TWD1645GE Engine + Stamford Alternator + Deep Sea Controls

1500KW: Dual Core HDI DP22CAS Engine + Stamford Alternator + Deep Sea Controls

1800KW: Dual Core HDI DP222CCS Engine + Stamford Alternator + Deep Sea Controls

2000KW: Quad Core HDI DX15 Engine + Stamford Alternator + Deep Sea Controls

2500KW: Quad Core Volvo TWD1645GE Engine + Stamford Alternator + Deep Sea Controls

3000KW: Quad Core HDI DP22CAS Engine + Stamford Alternator + Deep Sea Controls

3600KW: Quad Core HDI DP222CCS Engine + Stamford Alternator + Deep Sea Controls

4000KW: Octa Core HDI DX15 Engine + Stamford Alternator + Deep Sea Controls

5000KW: Octa Core Volvo TWD1645GE Engine + Stamford Alternator + Deep Sea Controls

6000KW: Octa Core HDI DP22CAS Engine + Stamford Alternator + Deep Sea Controls

7200KW: Octa Core HDI DP222CCS Engine + Stamford Alternator + Deep Sea Controls

Power Pack Diesel Prime Power Options

1000KW: Dual Core Volvo TWD1672GE Engine + Stamford Alternator + Deep Sea Controls

1250KW: Dual Core Volvo TWD1673GE Engine + Stamford Alternator + Deep Sea Controls

2000KW: Quad Core Volvo TWD1672GE Engine + Stamford Alternator + Deep Sea Controls

2500KW: Quad Core Volvo WD1673GE Engine + Stamford Alternator + Deep Sea Controls

4000KW: Octa Core Volvo TWD1672GE Engine + Stamford Alternator + Deep Sea Controls

5000KW: Octa Core Volvo TWD1673GE Engine + Stamford Alternator + Deep Sea Controls

Power Pack Gaseous Emergency Standby Power Options

250KW: Dual Core Origin OE62L125TC Engine + Stamford Alternator + Deep Sea Controls

300KW: Dual Core Origin OE91L150TC Engine + Stamford Alternator + Deep Sea Controls

400KW: Dual Core Origin OE103L200TC Engine + Stamford Alternator + Deep Sea Controls

500KW: Dual Core Origin OE103L250TC Engine + Stamford Alternator + Deep Sea Controls

800KW: Quad Core Origin OE103L200TC Engine + Stamford Alternator + Deep Sea Controls

880KW: Dual Core Mesa GV22PU Engine + Stamford Alternator + Deep Sea Controls

1000KW: Dual Core Zenith Z12240 Engine + Stamford Alternator + Deep Sea Controls

1000KW: Quad Core Origin OE103L250TC Engine + Stamford Alternator + Deep Sea Controls

1760KW: Quad Core Mesa GV22PU Engine + Stamford Alternator + Deep Sea Controls

2000KW: Quad Core Zenith Z12240 Engine + Stamford Alternator + Deep Sea Controls

3520KW: Octa Core Mesa GV22PU Engine + Stamford Alternator + Deep Sea Controls

Power Pack Gaseous Prime Power Options

300KW: Dual Core Zenith Z690TA Engine + Stamford Alternator + Deep Sea Controls

350KW: Dual Core Zenith Z690TA Engine + Stamford Alternator + Deep Sea Controls

780KW: Dual Core Mesa GV22PU Engine + Stamford Alternator + Deep Sea Controls

1560KW: Quad Core Mesa GV22PU Engine + Stamford Alternator + Deep Sea Controls

Designing The Proper PowerPack

Our Operations and Engineering departments will analyze each project to help determine the best solution for the application and duty cycle. Frequently asked questions when designing a WILDCAT PowerPack power solution include:

  1. Is the switchgear currently on site? If so, is there a breaker bucket position that will allow for direct utility tie?

  2. What is the required voltage?

  3. What is the maximum amperage rating required?

  4. Who is the utility and what are their protective relaying requirements?

  5. Are there any real estate constraints for the generator enclosure?

  6. What is the desired fuel: Natural Gas, Propane, or Diesel?

  7. What is the decibel requirement at 7 meters?

  8. Is this a distributed energy project?

  9. Will there be any generator power sold back to the grid?